What conditions can be met to build color steel plank houses? The construction of color steel plank houses must first meet the safety and fire protection requirements, such as:
彩鋼板房不得設(shè)置在高壓線下,也不得設(shè)置在溝邊、崖邊、江河岸邊、強(qiáng)風(fēng)口處等影響的地點(diǎn);
The color steel plank house shall not be set under the high-voltage line, or at the ditch edge, cliff edge, river bank, strong wind outlet and other places that affect the safety;
彩鋼板房實(shí)行封閉管理,與作業(yè)區(qū)、居民區(qū)要保持有效距離;
The color steel plank house shall be closed and managed, and shall be kept at an effective distance from the operation area and residential area;
人員密集場(chǎng)所嚴(yán)禁搭建易燃、可燃夾芯材料彩鋼板房;
It is strictly prohibited to build color steel plate houses with flammable and combustible sandwich materials in densely populated areas;
彩鋼板房不得占用消防通道、防火間距。
The color steel plate room shall not occupy the fire passage and fire separation.
此外要采取一定的措施來確保防火,如下:
In addition, certain measures shall be taken to ensure fire safety, as follows:
先要選用經(jīng)過檢驗(yàn)合格的A級(jí)不燃材料(巖棉、玻璃絲棉)作為芯材,這是治本的方法。在設(shè)計(jì)、施工時(shí),要規(guī)范劃分防火分區(qū),防火分區(qū)可將火災(zāi)限制在建筑的某一部分,從而降低損失,同時(shí)應(yīng)留下可靠的救生通道。
First, we should select Class A non combustible materials (rock wool, glass wool) that have passed the inspection as the core materials, which is a permanent solution. During the design and construction, the fire compartment shall be divided in a standardized way. The fire compartment can limit the fire to a certain part of the building, so as to reduce losses. At the same time, a safe and reliable life-saving passage shall be left.
在搭建過程中,芯材要遠(yuǎn)離電焊、氣焊等明火作業(yè)。施工場(chǎng)所要配備簡(jiǎn)易滅火器材,有條件的應(yīng)加裝火災(zāi)報(bào)警器,方便人員快速撤離;合理選用彩鋼板房防火保護(hù)方法,采用外包層充水、屏蔽、膨脹材料,以增強(qiáng)其耐火極限。
During the construction, the core materials shall be kept away from open flame operations such as electric welding and gas welding. The construction site shall be equipped with simple fire fighting equipment, and if possible, fire alarm shall be installed to facilitate rapid evacuation of personnel; The fire protection method of color steel plate room shall be reasonably selected, and the outer layer shall be filled with water, shielding and expansion materials to enhance its fire resistance limit.
在使用過程中,一些熱源、火源不要緊挨著鋼板,要保持一定距離(彩鋼板房之間少要保持6米的距離)。如果要在彩鋼板房?jī)?nèi)設(shè)置廚房,需要有隔溫層,墻面應(yīng)加裝防火巖棉隔熱層;電線、電纜嚴(yán)禁從芯材中穿過,如需要穿過應(yīng)加裝保護(hù)套管,插座、開關(guān)盒應(yīng)采用金屬鍍鋅盒并明裝。
In the process of use, some heat sources and ignition sources should not be close to the steel plate, and a certain distance should be kept (a safe distance of at least 6 meters should be kept between color steel plate houses). If the kitchen is to be set in the color steel plate room, a thermal insulation layer is required, and the wall should be equipped with a fireproof rock wool thermal insulation layer; Wires and cables are not allowed to pass through the core materials. If it is necessary to pass through, protective sleeves should be installed. The sockets and switch boxes should be metal galvanized boxes and installed openly.
制定相關(guān)制度,建立問責(zé)機(jī)制。建設(shè)單位、施工有關(guān)單位責(zé)任人要認(rèn)真學(xué)習(xí)相關(guān)法律法規(guī)和政策,確定消防責(zé)任人、消防管理人,并明確各崗位負(fù)責(zé)人的消防責(zé)任;加強(qiáng)設(shè)計(jì)、施工過程的檢查和監(jiān)督,一旦發(fā)現(xiàn)問題或隱患要立即整改。更多相關(guān)內(nèi)容就來我們網(wǎng)站
http://nhmmgs.com咨詢吧!
Formulate relevant systems and establish accountability mechanisms. The person in charge of the construction unit and relevant construction units shall carefully study relevant laws, regulations and policies, determine the person in charge of fire protection and fire safety manager, and define the fire safety responsibilities of the person in charge of each post; Strengthen the inspection and supervision of the design and construction process, and immediately rectify any problems or hidden dangers found. More relevant content will come to our website http://nhmmgs.com Consult!